Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.737
Filtrar
1.
Yi Chuan ; 46(4): 306-318, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38632093

RESUMO

With the increasing number of complex forensic cases in recent years, it's more important to combine the different types of genetic markers such as short tandem repeats (STRs), single nucleotide polymorphisms (SNPs), insertion/deletion polymorphisms (InDels), and microhaplotypes (MHs) to provide more genetic information. In this study, we selected totally 201 genetic markers, including 24 autosomes STRs (A-STRs), 24 Y chromosome STRs (Y-STRs), 110 A-SNPs, 24 Y-SNPs, 9 A-InDels, 1 Y-InDel, 8 MHs, and Amelogenin to establish the HID_AM Panel v1.0, a Next-Generation Sequencing (NGS) detection system. According to the validation guidelines of the Scientific Working Group on DNA Analysis Methods (SWGDAM), the repeatability, accuracy, sensitivity, suitability for degraded samples, species specificity, and inhibitor resistance of this system were assessed. The typing results on 48 STRs and Amelogenin of this system were completely consistent with those obtained using capillary electrophoresis. This system accurately detected 79 SNPs as parallelly confirmed by a FGx sequencer with the ForenSeq™ DNA Signature Prep Kit. Complete allele typing results could be obtained with a DNA input of no less than 200 pg. The detection success rate of this system was significantly higher than that of the GlobalFiler™ kit when the degradation index of mock degraded sample was greater than 15.87. When the concentration of hematin in the amplification system was ≤40 µmol/L, indigo blue was ≤2 mmol/L, or humic acid was ≤15 ng/µL, amplification was not significantly inhibited. The system barely amplified the DNA extract from duck, mouse, cow, rabbit, and chick. The detection rate of STRs on routine samples of this panel is 99.74%, while all the SNPs, InDels, and MHs were successfully detected. In summary, we setup a NGS individual typing panel including 201 genetic markers with the high accuracy, sensitivity, species specificity, and inhibitors resistance, which is applicable for individual identification of degraded samples.


Assuntos
Impressões Digitais de DNA , Polimorfismo de Nucleotídeo Único , Feminino , Bovinos , Animais , Camundongos , Coelhos , Impressões Digitais de DNA/métodos , Marcadores Genéticos , Amelogenina/genética , Genótipo , Reação em Cadeia da Polimerase , Reprodutibilidade dos Testes , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Repetições de Microssatélites , DNA , Análise de Sequência de DNA/métodos
2.
Forensic Sci Int ; 357: 111971, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38447344

RESUMO

Short tandem repeats (STRs) or microsatellites are short, tandemly repeated DNA sequences that involve a repetitive unit of 1-6 bp. DNA isolation and purification from a large number and often compromised samples gives problems to forensic labs for STR typing. Many of the conventional methods used in the isolation and purification of DNA from forensic samples are time consuming, expensive, hazardous for health and are often associated with greater risks of cross contamination. FTA® technology is a method designed to simplify the collection, shipment, archiving and purification of nucleic acid from a wide variety of biological samples. We report a new method for the direct STR amplification which can amplify STR loci from human foetal tissues spotted on FTA cards, bye-passing the need of DNA purification. The STR loci amplified by this method was compared with conventional method of STR profiling and was found absolutely matching. Therefore, this new method is demonstrated to be very useful for fast, less expensive and non- hazardous forensic DNA analysis.


Assuntos
Impressões Digitais de DNA , DNA , Humanos , Reação em Cadeia da Polimerase/métodos , Impressões Digitais de DNA/métodos , DNA/análise , Repetições de Microssatélites
3.
Mol Biol Rep ; 51(1): 430, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38517597

RESUMO

BACKGROUND: Short tandem repeats (STRs) are the most widely used genetic markers in forensic genetics. Therefore, it is essential to document genetic population data of new kits designed for human identification purposes to enable laboratories to use these genetic systems to interpret and solve forensic casework. However, in Mexico, there are no studies with the PowerPlex Fusion 6C System, which includes 26 STRs (23 autosomal STRs and 3 Y-STRs). METHODS AND RESULTS: 600 DNA samples from Mexico City were subjected to genotyping using the PowerPlex Fusion 6C System. For autosomal STRs, 312 different alleles were observed. Combined PE and PD were 99.999999809866% and 99.99999999999999999999999818795%, respectively. Genetic distances and AMOVA test showed low but significant differentiation between Mexican populations. CONCLUSIONS: The results reported in this work demonstrate the efficacy of this system for human identification purposes in the population studied and justify its possible application in other Mexican Mestizo populations.


Assuntos
Impressões Digitais de DNA , Genética Populacional , Humanos , Frequência do Gene/genética , México , Impressões Digitais de DNA/métodos , Repetições de Microssatélites/genética
4.
Forensic Sci Int Genet ; 70: 103031, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38493735

RESUMO

Blood-containing mixtures are frequently encountered at crime scenes involving violence and murder. However, the presence of blood, and the association of blood with a specific donor within these mixtures present significant challenges in forensic analysis. In light of these challenges, this study sought to address these issues by leveraging blood-specific methylation sites and closely linked microhaplotype sites, proposing a novel composite genetic marker known as "blood-specific methylation-microhaplotype". This marker was designed to the detection of blood and the determination of blood donor within blood-containing mixtures. According to the selection criteria mentioned in the Materials and Methods section, we selected 10 blood-specific methylation-microhaplotype loci for inclusion in this study. Among these loci, eight exhibited blood-specific hypomethylation, while the remaining two displayed blood-specific hypermethylation. Based on data obtained from 124 individual samples in our study, the combined discrimination power (CPD) of these 10 successfully sequenced loci was 0.999999298. The sample allele methylation rate (Ram) was obtained from massive parallel sequencing (MPS), which was defined as the proportion of methylated reads to the total clustered reads that were genotyped to a specific allele. To develop an allele type classification model capable of identifying the presence of blood and the blood donor, we used the Random Forest algorithm. This model was trained and evaluated using the Ram distribution of individual samples and the Ram distribution of simulated shared alleles. Subsequently, we applied the developed allele type classification model to predict alleles within actual mixtures, trying to exclude non-blood-specific alleles, ultimately allowing us to identify the presence of blood and the blood donor in the blood-containing mixtures. Our findings demonstrate that these blood-specific methylation-microhaplotype loci have the capability to not only detect the presence of blood but also accurately associate blood with the true donor in blood-containing mixtures with the mixing ratios of 1:29, 1:19, 1:9, 1:4, 1:2, 2:1, 7:1, 8:1, 31:1 and 36:1 (blood:non-blood) by DNA mixture interpretation methods. In addition, the presence of blood and the true blood donor could be identified in a mixture containing four body fluids (blood:vaginal fluid:semen:saliva = 1:1:1:1). It is important to note that while these loci exhibit great potential, the impact of allele dropouts and alleles misidentification must be considered when interpreting the results. This is a preliminary study utilising blood-specific methylation-microhaplotype as a complementary tool to other well-established genetic markers (STR, SNP, microhaplotype, etc.) for the analysis in blood-containing mixtures.


Assuntos
Doadores de Sangue , Líquidos Corporais , Feminino , Humanos , Marcadores Genéticos , Genótipo , Metilação de DNA , Impressões Digitais de DNA/métodos , Polimorfismo de Nucleotídeo Único , Genética Forense
5.
Genes (Basel) ; 15(2)2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38397140

RESUMO

In the realm of DNA testing with legal implications, the reliability and precision of genetic markers play a pivotal role in confirming or negating paternity claims. This study aimed to assess the potential utility of human leukocyte antigen (HLA) gene polymorphism through massively parallel sequencing (MPS) technology as robust forensic markers for parentage testing involving genetic deficiencies. It sought to redefine the significance of HLA genes in this context. Data on autosomal short tandem repeat (aSTR) mutational events across 18 paternity cases involving 16 commonly employed microsatellite loci were presented. In instances where traditional aSTR analysis failed to establish statistical certainty, kinship determination was pursued via HLA genotyping, encompassing the amplification of 17 linked HLA loci. Within the framework of this investigation, phase-resolved genotypes for HLA genes were meticulously generated, resulting in the definition of 34 inherited HLA haplotypes. An impressive total of 274 unique HLA alleles, which were classified at either the field 3 or 4 level, were identified, including the discovery of four novel HLA alleles. Likelihood ratio (LR) values, which indicated the likelihood of the observed data under a true biological relationship versus no relationship, were subsequently calculated. The analysis of the LR values demonstrated that the HLA genes significantly enhanced kinship determination compared with the aSTR analysis. Combining LR values from aSTR markers and HLA loci yielded conclusive outcomes in duo paternity cases, showcasing the potential of HLA genes and MPS technology for deeper insights and diversity in genetic testing. Comprehensive reference databases and high-resolution HLA typing across diverse populations are essential. Reintegrating HLA alleles into forensic identification complements existing markers, creating a potent method for future forensic analysis.


Assuntos
Impressões Digitais de DNA , Paternidade , Polimorfismo Genético , Humanos , Alelos , Impressões Digitais de DNA/métodos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Antígenos HLA/genética , Reprodutibilidade dos Testes
6.
Forensic Sci Int Genet ; 70: 103024, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38335775

RESUMO

Tapelifting is a common strategy to recover touch DNA deposits from porous exhibits in forensic DNA casework. However, it is known that only about 30 % of tapelifts submitted for DNA analysis in operational forensic laboratories yield profiles suitable for comparison or upload to a searchable database. A reliable means to identify and remove non-probative tapelifts from the workflow would reduce sample backlogs and provide significant cost savings. We investigated whether the amount of macroscopic or microscopic fluorescence on a tapelift following staining with Diamond Nucleic Acid Dye (DD), determined using a Polilight and Dino Lite microscope respectively, could predict the DNA yield and/or the DNA profiling outcome using controlled (saliva), semi-controlled (finger mark) and uncontrolled (clothing) samples. Both macroscopic and microscopic DD fluorescence could predict DNA yield and profiling outcome for all sample types, however the predictive power deteriorated as the samples became less controlled. For tapelifts of clothing, which are operationally relevant, Polilight fluorescence scores were significantly impacted by clothing fibres and other non-cellular debris and could not be used to identify non-probative samples. The presence of less than 500 cells on a clothing tapelift using microscopic counting of stained corneocytes was identified as a potential threshold for a non-probative DNA profiling outcome. A broader examination of the reliability of this threshold using a casework trial is recommended. Due to the labour intensiveness of microscopic cell counting, and the increased risk of inadvertent contamination, automation of this process using image software in conjunction with artificial neural networks (ANN) should be explored.


Assuntos
Ácidos Nucleicos , Tato , Humanos , Reprodutibilidade dos Testes , DNA/genética , Pele , Impressões Digitais de DNA/métodos , Repetições de Microssatélites
7.
Forensic Sci Int Genet ; 70: 103025, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38382248

RESUMO

Missing person cases typically require a genetic kinship test to determine the relationship between an unidentified individual and the relatives of the missing person. When not enough genetic evidence has been collected the lack of statistical power of these tests might lead to unreliable results. This is particularly true when just a few distant relatives are available for genotyping. In this contribution, we considered a Bayesian network approach for kinship testing and proposed several information theoretic metrics in order to quantitatively evaluate the information content of pedigrees. We show how these statistics are related to the widely used likelihood ratio values and could be employed to efficiently prioritize family members in order to optimize the statistical power in missing person problems. Our methodology seamlessly integrates with Bayesian modeling approaches, like the GENis platform that we have recently developed for high-throughput missing person identification tasks. Furthermore, our approach can also be easily incorporated into Elston-Stewart forensic frameworks. To facilitate the application of our methodology, we have developed the forensIT package, freely available on CRAN repository, which implements all the methodologies described in our manuscript.


Assuntos
Impressões Digitais de DNA , Teoria da Informação , Humanos , Impressões Digitais de DNA/métodos , Funções Verossimilhança , Teorema de Bayes , Linhagem
8.
Forensic Sci Int Genet ; 70: 103026, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38412740

RESUMO

In forensics investigations, it is common to encounter biological mixtures consisting of homogeneous or heterogeneous components from multiple individuals and with different genetic contributions. One promising mixture deconvolution strategy is the DEPArray™ technology, which enables the separation of cell populations before genetic analysis. While technological advances are fundamental, their reliable validation is crucial for successful implementation and use for casework. Thus, this study aimed to 1) systematically validate the DEPArray™ system concerning specificity, sensitivity, repeatability, and contamination occurrences for blood, epithelial, and sperm cells, and 2) evaluate its potential for single-cell analysis in the field of forensic science. Our findings confirmed the effective identification of different cell types and the correct assignment of successfully genotyped single cells to their respective donor(s). Using the NGM Detect™ Amplification Kit, the average profile completeness for diploid cells was approximately 80%, with ∼ 290 RFUs. In contrast, haploid sperm analysis yielded an average completeness of 51% referring to the haploid reference profile, accompanied by mean peak heights of ∼ 176 RFUs. Although certain alleles of heterozygous loci in diploid cells showed strong imbalances, the overall peak balances yielded acceptable values above ≥ 60% with a mean value of 72% ± 0.21, a median of 77%, but with a maximum imbalance of 9% between heterozygous peaks. Locus dropouts were considered stochastic events, exhibiting variations among donors and cell types, with a notable failure incidence observed for TH01. Within the wet-lab experimentation with >500 single cells for the validation, profiling was performed using the consensus approach, where profiles were selected randomly from all data to better mirror real casework results. Nevertheless, complete profiles could be achieved with as few as three diploid cells, while the average success rate increased to 100% when using profiles of 6-10 cells. For sperms, however, a consensus profile with completeness >90% of the autosomal diploid genotype could be attained using ≥15 cells. In addition, the robustness of the consensus approach was evaluated in the absence of the respective reference profile without severe deterioration. Here, increased stutter peaks (≥ 15%) were found as the main artifact in single-cell profiles, while contamination and drop-ins were ascertained as rare events. Lastly, the technique's potential and limitations are discussed, and practical guidance is provided, particularly valuable for cold cases, multiple perpetrator rapes, and analyses of homogeneous mixed evidence.


Assuntos
Impressões Digitais de DNA , Sêmen , Humanos , Masculino , Impressões Digitais de DNA/métodos , Repetições de Microssatélites , Reação em Cadeia da Polimerase/métodos , Espermatozoides
9.
J Forensic Sci ; 69(3): 836-846, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38366747

RESUMO

Badly burned skeletal remains are commonly submitted to forensic laboratories for victim identification via DNA analysis methods. Burned skeletal remains present many challenges for DNA analysis as they can contain low amounts of DNA which can also be damaged and degraded, resulting in partial or no STR profiles. Therefore, a simple, but effective screening method that identifies which samples may provide the most successful STR or mtDNA typing results for identification would enable forensic laboratories to save time, money, and resources. One metric that can be used and a screening method is the color of burned bone, as bone color changes with exposure to fire as temperature and length of exposure increase. This research developed a quantitative screening method based on the surface color of burned bone. The different visual bone colors (light brown, dark brown, black, gray, and white) were quantified using the Commission on Illumination L*a*b color space. These values were then compared to DNA yield, STR, and mtDNA profile completeness to identify whether the L*a*b values can predict genotyping success. A Bayesian network was constructed to determine the probability of STR typing success, given a set of L*a*b values. Results demonstrated that samples with an a* value greater than or equal to one and b* value greater than eight (light brown and dark brown burned samples) were the most predictive of STR typing success and mtDNA typing success. A decision tree for processing burned bones was constructed based on the color value thresholds.


Assuntos
Osso e Ossos , Cor , Impressões Digitais de DNA , DNA Mitocondrial , DNA , Incêndios , Genótipo , Repetições de Microssatélites , Humanos , Impressões Digitais de DNA/métodos , DNA Mitocondrial/genética , Osso e Ossos/química , Queimaduras/patologia , Teorema de Bayes , Antropologia Forense/métodos , Reação em Cadeia da Polimerase
10.
Mol Genet Genomics ; 299(1): 9, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38374461

RESUMO

Currently, the most commonly used method for human identification and kinship analysis in forensic genetics is the detection of length polymorphism in short tandem repeats (STRs) using polymerase chain reaction (PCR) and capillary electrophoresis (CE). However, numerous studies have shown that considerable sequence variations exist in the repeat and flanking regions of the STR loci, which cannot be identified by CE detection. Comparatively, massively parallel sequencing (MPS) technology can capture these sequence differences, thereby enhancing the identification capability of certain STRs. In this study, we used the ForenSeq™ DNA Signature Prep Kit to sequence 58 STRs and 94 individual identification SNPs (iiSNPs) in a sample of 220 unrelated individuals from the Eastern Chinese Han population. Our aim is to obtain MPS-based STR and SNP data, providing further evidence for the study of population genetics and forensic applications. The results showed that the MPS method, utilizing sequence information, identified a total of 486 alleles on autosomal STRs (A-STRs), 97 alleles on X-chromosome STRs (X-STRs), and 218 alleles on Y-chromosome STRs (Y-STRs). Compared with length polymorphism, we observed an increase of 260 alleles (157, 31, and 72 alleles on A-STRs, X-STRs, and Y-STRs, respectively) across 36 STRs. The most substantial increments were observed in DYF387S1 and DYS389II, with increases of 287.5% and 250%, respectively. The most increment in the number of alleles was found at DYF387S1 and DYS389II (287.5% and 250%, respectively). The length-based (LB) and sequence-based (SB) combined random match probability (RMP) of 27 A-STRs were 6.05E-31 and 1.53E-34, respectively. Furthermore, other forensic parameters such as total discrimination power (TDP), cumulative probability of exclusion of trios (CPEtrio), and duos (CPEduo) were significantly improved when using the SB data, and informative data were obtained for the 94 iiSNPs. Collectively, these findings highlight the advantages of MPS technology in forensic genetics, and the Eastern Chinese Han genetic data generated in this study could be used as a valuable reference for future research in this field.


Assuntos
Impressões Digitais de DNA , Etnicidade , Humanos , Impressões Digitais de DNA/métodos , Etnicidade/genética , Genética Populacional , Polimorfismo de Nucleotídeo Único/genética , Repetições de Microssatélites/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , China , DNA , Análise de Sequência de DNA/métodos
11.
Forensic Sci Int Genet ; 69: 103002, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38176092

RESUMO

Shedder status is defined as the propensity of an individual to leave DNA behind on touched items or surfaces and has been suggested as one of the major factors influencing DNA transfer. However, little is known about whether shedder status is a constant property of an individual across multiple measurements or when the environmental conditions are changed. We have assessed DNA depositions of six males on 20 occasions to acquire a reference data set and to classify the participants into high, intermediate, or low shedders. This data set was also used to investigate how the probability of a correct shedder status classification changed when the number of DNA deposition measurements increased. Individual sweat rates were measured with a VapoMeter and data regarding hygiene routines were collected through a questionnaire on each sampling occasion. Next, we investigated how changes in the experimental conditions such as seasonal variation, hygiene routines, the temperature of the touched object, and repeated handling of an object influenced the DNA shedding. Additionally, we assessed DNA collected from the face and from T-shirts worn by the six participants to explore whether shedder status may be associated with the relative amount of DNA obtained from other body parts. Our results indicate that shedder status is a stable property across different seasons and different temperatures of handled objects. The relative DNA amounts obtained from repeatedly handled tubes, worn T-shirts, and from faces reflected the shedder status of the participants. We suggest that an individual's shedder status is highly influenced by the DNA levels on other body parts than hands, accumulating on the palms by frequently touching e.g., the face or previously handled items harboring self-DNA. Assessing physiological differences between the participants revealed that there were no associations between DNA shedding and individual sweat rates.


Assuntos
DNA , Tato , Masculino , Humanos , DNA/genética , Mãos , Probabilidade , Impressões Digitais de DNA/métodos
12.
Forensic Sci Int Genet ; 69: 103000, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38199167

RESUMO

In the absence of a suspect the forensic aim is investigative, and the focus is one of discerning what genotypes best explain the evidence. In traditional systems, the list of candidate genotypes may become vast if the sample contains DNA from many donors or the information from a minor contributor is swamped by that of major contributors, leading to lower evidential value for a true donor's contribution and, as a result, possibly overlooked or inefficient investigative leads. Recent developments in single-cell analysis offer a way forward, by producing data capable of discriminating genotypes. This is accomplished by first clustering single-cell data by similarity without reference to a known genotype. With good clustering it is reasonable to assume that the scEPGs in a cluster are of a single contributor. With that assumption we determine the probability of a cluster's content given each possible genotype at each locus, which is then used to determine the posterior probability mass distribution for all genotypes by application of Bayes' rule. A decision criterion is then applied such that the sum of the ranked probabilities of all genotypes falling in the set is at least 1-α. This is the credible genotype set and is used to inform database search criteria. Within this work we demonstrate the salience of single-cell analysis by performance testing a set of 630 previously constructed admixtures containing up to 5 donors of balanced and unbalanced contributions. We use scEPGs that were generated by isolating single cells, employing a direct-to-PCR extraction treatment, amplifying STRs that are compliant with existing national databases and applying post-PCR treatments that elicit a detection limit of one DNA copy. We determined that, for these test data, 99.3% of the true genotypes are included in the 99.8% credible set, regardless of the number of donors that comprised the mixture. We also determined that the most probable genotype was the true genotype for 97% of the loci when the number of cells in a cluster was at least two. Since efficient investigative leads will be borne by posterior mass distributions that are narrow and concentrated at the true genotype, we report that, for this test set, 47,900 (86%) loci returned only one credible genotype and of these 47,551 (99%) were the true genotype. When determining the LR for true contributors, 91% of the clusters rendered LR>1018, showing the potential of single-cell data to positively affect investigative reporting.


Assuntos
Impressões Digitais de DNA , Repetições de Microssatélites , Humanos , Impressões Digitais de DNA/métodos , Teorema de Bayes , Genótipo , DNA/genética , Funções Verossimilhança
13.
Forensic Sci Int Genet ; 69: 103009, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38237274

RESUMO

Population data have become available for sequence data to aid forensic investigations and prepare the forensic community in the move towards implementing NGS methods. This comes with a need for updated population genetic parameters estimates to allow DNA evidence evaluations using sequence data. Initial work has been done on a small sample and here we expand this work by providing estimates of population structure and relatedness for autosomal STR data generated by sequencing technologies. We also discuss the effect of inbreeding on forensic calculations and discuss why the use of genotypic-based estimates may be preferred over allelic-based estimates.


Assuntos
Genética Forense , Endogamia , Humanos , Genética Forense/métodos , Repetições de Microssatélites , Genótipo , DNA/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Análise de Sequência de DNA/métodos , Impressões Digitais de DNA/métodos
14.
Forensic Sci Int Genet ; 69: 103008, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38244524

RESUMO

Inferring the number of contributors (NoC) is a crucial step in interpreting DNA mixtures, as it directly affects the accuracy of the likelihood ratio calculation and the assessment of evidence strength. However, obtaining the correct NoC in complex DNA mixtures remains challenging due to the high degree of allele sharing and dropout. This study aimed to analyze the impact of allele sharing and dropout on NoC inference in complex DNA mixtures when using microhaplotypes (MH). The effectiveness and value of highly polymorphic MH for NoC inference in complex DNA mixtures were evaluated through comparing the performance of three NoC inference methods, including maximum allele count (MAC) method, maximum likelihood estimation (MLE) method, and random forest classification (RFC) algorithm. In this study, we selected the top 100 most polymorphic MH from the Southern Han Chinese (CHS) population, and simulated over 40 million complex DNA mixture profiles with the NoC ranging from 2 to 8. These profiles involve unrelated individuals (RM type) and related pairs of individuals, including parent-offspring pairs (PO type), full-sibling pairs (FS type), and second-degree kinship pairs (SE type). Our results indicated that how the number of detected alleles in DNA mixture profiles varied with the markers' polymorphism, kinship's involvement, NoC, and dropout settings. Across different types of DNA mixtures, the MAC and MLE methods performed best in the RM type, followed by SE, FS, and PO types, while RFC models showed the best performance in the PO type, followed by RM, SE, and FS types. The recall of all three methods for NoC inference were decreased as the NoC and dropout levels increased. Furthermore, the MLE method performed better at low NoC, whereas RFC models excelled at high NoC and/or high dropout levels, regardless of the availability of a priori information about related pairs of individuals in DNA mixtures. However, the RFC models which considered the aforementioned priori information and were trained specifically on each type of DNA mixture profiles, outperformed RFC_ALL model that did not consider such information. Finally, we provided recommendations for model building when applying machine learning algorithms to NoC inference.


Assuntos
Algoritmos , Impressões Digitais de DNA , Humanos , Genótipo , Impressões Digitais de DNA/métodos , DNA/genética , Aprendizado de Máquina
15.
J Forensic Sci ; 69(3): 814-824, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38291825

RESUMO

DNA analysis of forensic case samples relies on short tandem repeats (STRs), a key component of the combined DNA index system (CODIS) used to identify individuals. However, limitations arise when dealing with challenging samples, prompting the exploration of alternative markers such as single nucleotide polymorphisms (SNPs) and insertion/deletion (INDELs) polymorphisms. Unlike SNPs, INDELs can be differentiated easily by size, making them compatible with electrophoresis methods. It is possible to design small INDEL amplicons (<200 bp) to enhance recovery from degraded samples. To this end, a set of INDEL Human Identification Markers (HID) was curated from the 1000 Genomes Project, employing criteria including a fixation index (FST) ≤ 0.06, minor allele frequency (MAF) >0.2, and high allele frequency divergence. A panel of 33 INDEL-HIDs was optimized and validated following the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines, utilizing a five-dye multiplex electrophoresis system. A small sample set (n = 79 unrelated individuals) was genotyped to assess the assay's performance. The validation studies exhibited reproducibility, inhibition tolerance, ability to detect a two-person mixture from a 4:1 to 1:6 ratio, robustness with challenging samples, and sensitivity down to 125 pg of DNA. In summary, the 33-loci INDEL-HID panel exhibited robust recovery with low-template and degraded samples and proved effective for individualization within a small sample set.


Assuntos
Impressões Digitais de DNA , Frequência do Gene , Mutação INDEL , Humanos , Impressões Digitais de DNA/métodos , Reprodutibilidade dos Testes , Marcadores Genéticos , Genótipo , Corantes Fluorescentes , Reação em Cadeia da Polimerase , Polimorfismo Genético , Eletroforese Capilar , Repetições de Microssatélites
16.
Forensic Sci Int Genet ; 70: 103010, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38271830

RESUMO

The worldwide implementation of short tandem repeats (STR) profiles in forensic genetics necessitated establishing and expanding the CODIS core loci set to facilitated efficient data management and exchange. Currently, the mainstay CODIS STRs are adopted in most general-purpose forensic kits. However, relying solely on these loci failed to yield satisfactory results for challenging tasks, such as bio-geographical ancestry inference, complex DNA mixture profile interpretation, and distant kinship analysis. In this context, non-CODIS STRs are potent supplements to enhance the systematic discriminating power, particularly when combined with the high-throughput next-generation sequencing (NGS) technique. Nevertheless, comprehensive evaluation on non-CODIS STRs in diverse populations was scarce, hindering their further application in routine caseworks. To address this gap, we investigated genetic variations of 178 historically available non-CODIS STRs from ethnolinguistically different worldwide populations and studied their characteristics and forensic potentials via high-coverage whole genome sequencing (WGS) data. Initially, we delineated the genomic properties of these non-CODIS markers through sequence searching, repeat structure scanning, and manual inspection. Subsequent population genetics analysis suggested that these non-CODIS STRs had comparable polymorphism levels and forensic utility to CODIS STRs. Furthermore, we constructed a theoretical next-generation sequencing (NGS) panel comprising 108 STRs (20 CODIS STRs and 88 non-CODIS STRs), and evaluated its performance in inferring bio-geographical ancestry origins, deconvoluting complex DNA mixtures, and differentiating distant kinships using real and simulated datasets. Our findings demonstrated that incorporating supplementary non-CODIS STRs enabled the extrapolation of multidimensional information from a single STR profile, thereby facilitating the analysis of challenging forensic tasks. In conclusion, this study presents an extensive genomic landscape of forensic non-CODIS STRs among global populations, and emphasized the imperative inclusion of additional polymorphic non-CODIS STRs in future NGS-based forensic systems.


Assuntos
Genética Populacional , Polimorfismo Genético , Humanos , DNA/genética , Genômica , Impressões Digitais de DNA/métodos , Análise de Sequência de DNA/métodos , Repetições de Microssatélites
17.
Forensic Sci Int Genet ; 70: 103012, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38295652

RESUMO

The autosomal STR D6S474 and the Y-chromosomal STR DYS612 have been reported in multiple ways in the forensic literature, with differences in both the bracketed repeat structures and counting of numerical length-based capillary electrophoresis (CE) alleles. These issues often come to light when STR loci are introduced in commercial assays and results compared with historical publications of allele frequency data, or multiple assays are characterized with reference materials. We review the forensic literature and other relevant information, and provide suggestions for the future treatment of each STR.


Assuntos
Impressões Digitais de DNA , Repetições de Microssatélites , Humanos , Impressões Digitais de DNA/métodos , Sequenciamento de Nucleotídeos em Larga Escala , Frequência do Gene , Alelos
18.
Forensic Sci Int Genet ; 69: 102996, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38061289

RESUMO

Forensic samples with low DNA template amounts are difficult to analyze and interpret. There is a large body of research demonstrating that adding carrier nucleic acid to storage tubes, solid phase extractions, or filtering devices can improve yields of target DNA. However, the addition of carrier nucleic acid to sampling substrates, like cotton swabs, has not yet been attempted. In this proof-of-concept study, carrier nucleic acids in the form of either Poly (A) RNA or salmon sperm DNA were spotted onto cotton swabs, followed by human genomic DNA, to determine if introducing the carrier prior to sample collection would increase recovery from the swabs post-extraction. Extracts were also evaluated to determine whether adding the carrier nucleic acids to human DNA would interfere with downstream forensic DNA analysis processes such as real-time PCR quantitation, PCR amplification of STR loci, or capillary electrophoresis. The RNA carrier did not improve human sample recovery from cotton swabs. The extraction efficiency of human DNA from cotton swabs was increased when the DNA carrier was applied to the swabs prior to sample deposition, and the scale of the increase depended on the amount of carrier DNA used. When applying the salmon sperm DNA carrier to cotton swabs, with each increase from no carrier to 0.001-1-10 µg, human DNA recovery went from ∼29 % to ∼50 % to ∼75 % to ∼100 %. Additionally, no inhibitory effects from the carrier DNA were observed post-extraction with quantitation or in the DNA profile after amplification. Therefore, salmon sperm DNA carrier will increase human DNA yield from cotton swabs without negative effects on downstream forensic DNA profiling methods, with the optimal carrier amount being 10 µg.


Assuntos
Salmão , Sêmen , Animais , Humanos , Masculino , Salmão/genética , Espermatozoides , Impressões Digitais de DNA/métodos , DNA/genética , Manejo de Espécimes/métodos , RNA
19.
Forensic Sci Int ; 354: 111887, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38007870

RESUMO

Two commercially available portable Rapid DNA instruments were evaluated for their ability to process 1 µL and 10 µL saliva samples deposited on metal and plastic surfaces and contaminated with surrogates of cesium (Cs)-137, strontium (Sr)-90 and cobalt (Co)-60; radioactive materials potentially released during a nuclear weapon accident or a radiological dispersal device detonation. A comparable success rate was noted for both Rapid DNA instruments when considering the number of complete and balanced DNA profiles, the number of profiles with a minimum of 10 autosomal STR loci (out of 23 [FlexPlex™ 27] or 21 [GlobalFiler™ Express]), and the possibility to search a national DNA database in Canada and the United States. Cobalt had an adverse impact on the quality of the megaplex short tandem repeat (STR) DNA profiles derived on each instrument for two of the three contamination levels tested in this study, i.e., 0.05 M and 0.1 M as reflected by a reduced number of detected alleles and decreased profile peak heights. Strontium exhibited some adverse effect on the Rapid DNA results when used at the highest contamination level (0.1 M) whereas cesium had none. No new artifacts were observed in the Rapid DNA profiles of samples spiked with the non-radiogenic surrogates. Importantly, in the context of a radiological/nuclear (RN) event, the ANDE™ 6C offers the possibility to dispose of all radioactive materials associated with contaminated samples quickly using a chip on which all steps of the Rapid DNA process are performed whereas the RapidHIT™ ID accumulates radioactive materials for many days before disposal. An individual handling 25 samples in a week (5 per day) on the RapidHIT™ ID at a 30.5 cm distance with a 5 min exposure to the radioactive source estimated at every run would exceed the 0.042 µSv/5 min limit with gamma dose rates for Cs at 0.13 mSv and for Co at 3.8 mSv. Beta dose rates calculated for the surrogate isotopes at the three concentrations tested were also above the recommended radiation exposure limit of 1 mSv/yr (0.042 µSv/5 min). Various potential mechanisms of action behind the interference noted for Sr and Co at high concentrations are presented. These elements may play a role in the steps prior to PCR (at the DNA molecule by binding to bases or to phosphate groups), during PCR (at the DNA polymerase as cofactors for catalytic sites), or even during amplified DNA fragment detection (as fluorescence quenchers).


Assuntos
Impressões Digitais de DNA , Terrorismo , Impressões Digitais de DNA/métodos , Reação em Cadeia da Polimerase , Repetições de Microssatélites , Mucosa Bucal/química , DNA/análise , Radioisótopos de Cobalto/análise , Radioisótopos de Césio/análise , Radioisótopos de Estrôncio/análise
20.
Int J Legal Med ; 138(2): 361-373, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37843624

RESUMO

The GA118-24B Genetic Analyzer (hereafter, "GA118-24B") is an independently developed capillary electrophoresis instrument. In the present research, we designed a series of validation experiments to test its performance at detecting DNA fragments compared to the Applied Biosystems 3500 Genetic Analyzer (hereafter, "3500"). Three commercially available autosomal short tandem repeat multiplex kits were used in this validation. The results showed that GA118-24B had acceptable spectral calibration for three kits. The results of accuracy and concordance studies were also satisfactory. GA118-24B showed excellent precision, with a standard deviation of less than 0.1 bp. Sensitivity and mixture studies indicated that GA118-24B could detect low-template DNA and complex mixtures as well as the results generated by 3500 in parallel experiments. Based on the experimental results, we set specific analytical and stochastic thresholds. Besides, GA118-24B showed superiority than 3500 within certain size ranges in the resolution study. Instead of conventional commercial multiplex kits, GA118-24B performed stably on a self-developed eight-dye multiplex system, which were not performed on 3500 Genetic Analyzer. We compared our validation results with those of previous research and found our results to be convincing. Overall, we conclude that GA118-24B is a stable and reliable genetic analyzer for forensic DNA identification.


Assuntos
Impressões Digitais de DNA , DNA , Humanos , Impressões Digitais de DNA/métodos , Reação em Cadeia da Polimerase/métodos , Repetições de Microssatélites , Eletroforese Capilar/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...